-40%

Fluke 1735 Three Phase Power Logger Analyst 10.24 kHz

$ 1264.56

Availability: 100 in stock
  • Item must be returned within: 30 Days
  • Condition: Seller refurbished
  • All returns accepted: Returns Accepted
  • Brand: Fluke
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • Refund will be given as: Money back or replacement (buyer's choice)
  • MPN: 1735

    Description

    ebay template
    The Following Items Are Included:
    Fluke 1735 Three-Phase Power Logger Analyst (BC# 42460-L/T*)
    Fluke 4-Phase Flexi Set
    Fluke 1735 Voltage Probe
    (4) Fluke Alligator Clips
    RS232 PC Interface Cable
    AC Adapter/Charger
    Hard Copy User Manual
    User Manual On CD-ROM
    Carrying Case (G)
    BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS!
    This Item Has A Current Calibration!
    Fluke 1735 Three-Phase Power Logger
    Verify Electrical System Capacity Before Adding Loads.
    The power quality meter measures most electrical power parameters, harmonics, and captures voltage events
    Includes Carrying Case & Accessories As Listed Above!
    Working Condition: Excellent
    Condition: Refurbished
    Calibrated: Yes
    Warranty:  1 YEAR WARRANTY
    Power quality logging, electrical load studies and energy consumption testing.
    The Fluke 1735 Power Logger is the ideal electrician or technician’s power meter for conducting energy studies and basic power quality logging. Set the Power Logger up in seconds with the included flexible current probes and color display. The power quality meter measures most electrical power parameters, harmonics, and captures voltage events.
    Applications
    Load studies
    - verify electrical system capacity before adding loads
    Energy assessments
    - quantify energy consumption before and after improvements to justify energy saving devices
    Harmonics measurements
    - uncover harmonic issues that can damage or disrupt critical equipment
    Voltage event capture
    - monitor for dips and swells that cause spurious resets or nuisance circuit breaker tripping
    Features
    Record power and associated parameters for up to 45 days
    Monitor maximum power demand over user-defined averaging periods
    Prove the benefit of efficiency improvements with energy consumption tests
    Measure harmonic distortion caused by electronic loads
    Improve reliability by capturing voltage dips and swells from load switching
    Easily confirm instrument setup with color display of waveforms and trends
    Measure all three phases and neutral with included 4 flexible current probes
    View graphs and generate reports with included Power Log software
    Compact, rugged design with IP65 case, 600 V CAT III
    Specifications
    General
    Display:
    ¼ VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast, text and graphics in color
    Quality:
    Developed, designed and manufactured according to DIN ISO 9001
    Memory:
    4 MB Flash memory, 3.5 MB for measuring data
    Interface:
    RS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS- 232 interface (9-pole extension cable)
    Sample rate:
    10.24 kHz
    Line frequency:
    50 Hz or 60 Hz, user-selectable, with automatic synchronization
    Power supply:
    NiMH battery-pack, with ac adapter (15 V to 20 V/0.8 A)
    Operation time with battery:
    Typical > 12 hours without backlight and > 6 hours with backlight high
    Dimensions:
    240 mm x 180 mm x 110 mm
    Weight:
    1.7 kg, including battery
    Ambient conditions
    Working temperature range:
    -10 °C to +50 °C
    Storage temperature range:
    -20 °C to +60 °C
    Operating temperature range:
    0 °C to +40 °C
    Reference temperature range:
    23 °C ± 2 °C
    Note:
    The above terms are defined in European Standards. To calculate the specification at any point in the working temperature range, use the temperature coefficient below.
    Temperature coefficient:
    ± 0.1 % of the measured value per °C from the reference
    Intrinsic error:
    Refers to reference temperature, maximum deviation is guaranteed for two years
    Operating error:
    Refers to operating temperature range, maximum deviation is guaranteed for two years
    Climatic class:
    C1 (IEC 654-1) -5 °C to +45 °C, 5% to 95% RH, no dew
    Housing:
    Cycoloy shock and scratch proof thermoplast V0-type (non-flammable) with rubber protection holster
    EMC
    Emission:
    IEC/EN 61326-1:1997 class B
    Immunity:
    IEC/EN 61326-1:1997
    Safety
    Safety:
    IEC 61010-1 600 V CAT III, double or reinforced insulation, pollution degree 2
    Protection:
    IP65; EN60529 (refers only to the main housing without the battery compartment)
    RMS values are measured with a 20 ms resolution.
    V-rms wye measurement
    Measuring range:
    57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/400 V/417 V/480 V ac
    Intrinsic error:
    ± (0.2% of measured value + 5 digits)
    Operating error:
    ± (0.5% of m. v. + 10 digit)
    Resolution:
    0.1 V
    V-rms delta measurement
    Measuring range:
    100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/690 V/720 V/830 V ac
    Intrinsic error:
    ± (0.2% of m. v. + 5 digit)
    Operating error:
    ± (0.5 % of m. v. + 10 digit)
    Resolution:
    0.1 V
    A-rms measurement
    Flexi set I ranges:
    15 A/150 A/3000 A rms (at sine)
    Current clamp ranges:
    1 A/10 A
    Resolution:
    0.01 A
    Ranges
    150 A/3000 A and 1 A/10 A
    Intrinsic error:
    ± (0.5 % of m. v. + 10 digit)
    Operating error:
    ± (1 % of m. v. + 10 digit)
    Ranges
    15 A
    Intrinsic error:
    ± (0.5 % of m. v. + 20 digit)
    Operating error:
    ± (1 % of m. v. + 20 digit)
    The errors of the current probes are not considered.
    By using Flexi-Set
    Flexi Set measuring error:
    ± (2% of m. v. + 10 digit)
    Position influence:
    ± (3 % of m. v. + 10 digit)
    CF (typical):
    2.83
    Note:
    When using Flexi Set please make sure to position the conductor opposite to the Flexi Set-lock
    Power measurement (P - Active, S - Apparent, Q- reactive, D - Distorting
    Measuring range:
    see V rms and A rms measurement
    Power errors are calculated by adding the errors of voltage and current
    Additional error due to power factor PF
    Specified error x (1-[PF])
    Maximum range with voltage range 830 V delta-connection and 3000 A current range is 2.490 MW, higher displayed values possible when using PTs and CTs with ratio feature
    Intrinsic error:
    ± (0.7 % of m.v. +15 digit)
    Resolution:
    1 kW
    Operating error:
    ± (1.5 % of m.v. + 20 digit)
    Typical range with voltage range 230 V wye connection and 150 A current range is 34.50 KW.
    Intrinsic error:
    ± (0.7 % of m.v. +15 digit)
    Resolution:
    1 W to 10 W
    Operating error:
    ± (1.5 % of m.v. + 20 digit)
    The errors of the current sensors themselves have not been considered.
    Energy measurement (kWh, KVAh, kVARh)
    Intrinsic error:
    ± (0.7 % of m.v.+ F variation error* + 15 digit)
    Resolution:
    1 W to 10 W
    Operating error:
    ± (1.5 % of m.v. + F variation error* + 20 digit)
    *Frequency variation error
    PF (Power factor)
    Range:
    0.000 to 1.000
    Resolution:
    0.001
    Accuracy:
    ±1 % of full scale
    Frequency measurement
    Measuring range:
    46 Hz to 54 Hz and 56 Hz to 64 Hz
    Intrinsic error:
    ± (0.2 % of m. v. + 5 digit)
    Operating error:
    ± (0.5 % of m. v.+ 10 digit)
    Resolution:
    0.01 Hz
    Harmonics
    Measuring range:
    To 50th harmonic (< 50 % of nom)
    Accuracy
    Vm, Im, THDV, THDI:
    IEC 61000-4-7:2002, Class II
    Vm ≥ 3% Vn:
    ± 5% Vm
    Vm < 3 % Vnom:
    ±0.15% Vnom
    Im ≥ 10 % Inom:
    ± 5% Im
    Im < 10 % Inom:
    ± 0 5% Inom
    THDV:
    for THD < 3% ± 0.15% at Vnom
    for THD ≥ 3% ± 5% at Vnom
    THDI:
    for THD < 10% ± 0.5% at Inom
    for THD ≥ 10% ± 5% at Inom
    Vnom:
    Normal voltage range
    Inom:
    Nominal current range
    Vm and Im are measured values of harmonic m
    Events
    Detection of voltage dips, voltage swells and voltage interruptions with a 10 ms resolution and measuring error of the half period sine wave of rms.
    Intrinsic error:
    ± (1% of m.v. + 10 digit)
    Operating error:
    ± (2% of m.v. + 10 digit)
    Resolution:
    0.1 V
    For full Fluke 1735 product specifications, please click here:
    Fluke 1735
    Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our
    Ebay Test Equipment Store
    . All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to
    contact us
    for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.
    Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!
    We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!
    We Ship World Wide!
    We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate".
    Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information.
    We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.
    We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed.
    Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale.
    Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections)
    A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment.
    Thank you
    ALL MAJOR CREDIT CARDS & PayPal ACCEPTED
    Sell Smarter with
    Kyozou
    .
    Inventory and Ecommerce Management