    Description

    ebay template
    The Following Items Are Included:
    Fluke 1736 Three-Phase Power Quality Logger Analyzer (BC# -L/T*)
    4-Phase Flexi-Set
    Voltage Test Lead
    Voltage Probe
    Alligator Clips
    AC Adapter/Charger
    User Manual On CD-ROM
    Carrying Case
    BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS!
    This Item Has A Current Calibration!
    Fluke 1736 Three-Phase Power Quality Logger
    Ideal test tool for conducting energy studies and basic power quality logging, the 1736 automatically captures and logs over 500 power quality parameters so you have more visibility into the data you need to optimize system reliability and savings.
    Includes Carrying Case & Accessories As Listed Above!
    Working Condition: Excellent
    Condition: Refurbished
    Calibrated: Yes
    Warranty:  1 YEAR WARRANTY
    Fluke 1736 Three Phase Power Quality Logger
    More visibility, reduced uncertainty and better power quality and energy consumption decisions
    The Fluke 1736 and 1738 Three-Phase Power Loggers built with Fluke Connect® mobile app and desktop software compatibility give you the data you need to make critical power quality and energy decisions in real-time. The ideal test tools for conducting energy studies and basic power quality logging, the 1736 and 1738 automatically capture and log over 500 power quality parameters so you have more visibility into the data you need to optimize system reliability and savings.
    An optimized user interface, flexible current probes, and an intelligent measurement verification function that allows you to reduce measurement errors by digitally verifying and correcting common connection errors makes setup easier than ever and reduces measurement uncertainty. Access and share data remotely with your team via the Fluke Connect® app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins. You can also quickly and easily chart and graph measurements to help identify issues and create detailed reports with the included Fluke Energy Analyze Plus software package.
    Measure all three phases and neutral with included 4 flexible current probes
    Comprehensive logging: More than 20 separate logging sessions can be stored on the instruments. In fact, all measured values are automatically logged so you never loose measurement trends. They can even be reviewed during logging sessions and before downloading for real-time analysis.
    Capture dips, swells, and inrush currents: includes event waveform snapshot and high resolution RMS profile, along with date, timestamp and severity to help pinpoint potential root causes of power quality issues
    Bright, color touch screen: Perform convenient in-the-field analysis and data checks with full graphical display
    Optimized user interface: Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function.
    Complete “in-the-field” setup through the front panel or Fluke Connect App: no need to return to the workshop for download and setup or to take a computer to the electrical panel
    Easy to use
    The four current probes are connected separately; the instrument automatically detects and scales the probes. The thin current probes are designed to easily get through tight conductor spacing and are easily set to 150 or 1500 A for high accuracy in nearly any application. An innovative tangle-free flat voltage lead makes connection simple and reliable and the instrument’s intelligent ‘Verify Connection’ feature automatically checks to make sure the instrument is connected correctly and can digitally correct common connection issues without having to disconnect measurement leads.
    The detachable power supply can be conveniently and safely powered directly from the measured circuit—no more searching for power outlets or having to run multiple extension cords to the logging location.
    Specifications:
    Accuracy
    Voltage
    Range: 1000 V
    Max. resolution: 0.1 V
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ± (0.2 % + 0.01 %)
    Frequency
    Range: 42.5 Hz to 69 Hz
    Max. resolution: 0.01 Hz
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ± (0.1 %)
    Aux input
    Range: ± 10 V dc
    Max. resolution: 0.1 mV
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ± (0.2 % + 0.02 %)
    Voltage min/max
    Range: 1000 V
    Max. resolution: 0.1 V
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ± (1 % + 0.1 %)
    Current min/max
    Range: defined by accessory
    Max. resolution: defined by accessory
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ± (5 % + 0.2 %)
    THD on voltage
    Range: 1000 %
    Max. resolution: 0.1 %
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ± 0.5
    THD on current
    Range: 1000 %
    Max. resolution: 0.1 %
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ± 0.5
    Voltage harmonics 2nd ... 50th
    Range: 1000 V
    Max. resolution: 0.1 V
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ≥ 10 V: ± 5 % of reading < 10 V: ± 0.5V
    Current harmonics 2nd ... 50th
    Range: defined by accessory
    Max. resolution: defined by accessory
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ≥ 3 % of current range: ± 5 % of reading < 3 % of current range: ± 0.15 % of range
    Unbalance
    Range: 100%
    Max. resolution: 0.1 %
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ± 0.2
    Electrical specifications
    Power supply
    Voltage range
    100 V to 500 V using safety plug input when powering from the measurement circuit
    100 V to 240 V using standard power cord (IEC 60320 C7)
    Power consumption
    Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
    Efficiency
    ≥ 68.2 % (in accordance with energy efficiency regulations)
    Maximum no-load consumption
    < 0.3 W only when powered using IEC 60320 input
    Mains power frequency
    50/60 Hz ± 15 %
    Battery
    Li-ion 3.7 V, 9.25 Wh, customer-replaceable
    On-battery runtime
    Four hours in standard operating mode, up to 5.5 hours in power saving mode
    Charging time
    < 6 hours
    Data acquisition
    Resolution
    16-bit synchronous sampling
    Sampling frequency
    10.24 kHz at 50/60 Hz, synchronized to mains frequency
    Input signal frequency
    50/60 Hz (42.5 to 69 Hz)
    Circuit types
    1-ϕ, 1-ϕ IT, split phase, 3-ϕ delta, 3-ϕ wye, 3-ϕ wye IT, 3-ϕ wye balanced, 3-ϕ Aron/Blondel (2-element delta), 3-ϕ delta open leg, currents only (load studies)
    Data storage
    Internal flash memory (not user replaceable)
    Memory size
    Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events
    Basic interval
    Measured parameters
    Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
    Averaging interval
    User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
    Averaging time min/max values
    Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30
    Aux, Power: 200ms
    Demand Interval (Energy Meter Mode)
    Measured parameters
    Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
    Interval
    User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
    Power quality measurements
    Measured parameter
    Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD
    Averaging interval
    10 min
    Individual harmonics
    2nd ...50th harmonic
    Total harmonic distortion
    Calculated on 50 harmonics
    Events
    Voltage: dips, swells, interruptions, current: inrush current
    Triggered recordings
    Full cycle RMS updated every half cycle of voltage and current (Urms1/2 according to IEC61000-4-30)
    Waveform of voltage and current
    Standards Compliance
    Harmonics
    IEC 61000-4-7: Class 1 IEEE 519 (short time harmonics)
    Power quality
    IEC 61000-4-30 Class S, IEC62586-1 (PQI-S device)
    Power
    IEEE 1459
    Power quality compliance
    EN50160 (for measured parameters)
    Interfaces
    USB-A
    File transfer via USB flash drive, firmware updates, max. supply current: 120 mA
    WiFi
    File transfer and remote control via direct connection or WiFi infrastructure
    Bluetooth
    Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1738, or 1736 upgrade option)
    USB-mini
    Data download device to PC
    Voltage inputs
    Number of inputs
    4 (3 phases and neutral)
    Maximum input voltage
    1000 Vrms, CF 1.7
    Input impedance
    10 MΩ
    Bandwidth
    42.5 Hz - 3.5 kHz
    Scaling
    1:1 and variable
    Measurement category
    1000 V CAT III/600 V CAT IV
    Current inputs
    Number of inputs
    4, mode selected automatically for attached sensor
    Input voltage
    Clamp input: 500 mVrms/50 mVrms; CF 2.8
    Rogowski coil input
    150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
    Range
    1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12”
    3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24”
    6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36”
    40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
    Bandwidth
    42.5 Hz - 3.5 kHz
    Scaling
    1:1 and variable
    Auxiliary inputs
    Number of inputs
    2
    Input range
    0 to ± 10 V dc, 1 reading/s
    Scale factor
    Format: mx + b (gain and offset) user configurable
    Displayed units
    User configurable (7 characters, for example, °C, psi, or m/s)
    Wireless connection
    Number of inputs
    2
    Supported modules
    Fluke Connect® 3000 series
    Acquisition
    1 reading/s
    Environmental specifications
    Operating temperature
    -10 °C to +50 °C (14 °F to 122 °F)
    Storage temperature
    -20 °C to +60 °C (−4 °F to 140 °F), with battery: -20 °C to +50 °C (−4 °F to 122 °F)
    Operating humidity
    10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH
    30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH
    40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH
    Operating altitude
    2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
    Storage altitude
    12,000 m
    Enclosure
    IP50 in accordance with EN60529
    Vibration
    MIL-T-28800E, Type 3, Class III, Style B
    Safety
    IEC 61010-1 IEC Mains Input: Overvoltage Category II, Pollution Degree 2 Voltage Terminals: Overvoltage Category IV, Pollution Degree 2
    IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V
    Electromagnetic compatibility (EMC)
    EN 61326-1: Industrial CISPR 11: Group 1, Class A
    Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)
    USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
    Temperature coefficient
    0.1 x accuracy specification/°C
    General specifications
    Color LCD display
    4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
    Dimensions
    Instrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)
    Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)
    Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in)
    Weight
    Instrument: 1.1 kg (2.5 lb)
    Power supply: 400 g (0.9 lb)
    Tamper protection
    Kensington lock slot
    For full Fluke 1736 Power Quality Analyzer product specifications, please click here:
    Fluke 1736
    Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our
    Ebay Test Equipment Store
    . All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to
    contact us
    for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.
    Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!
    We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!
    We Ship World Wide!
    We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate".
    Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information.
    We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.
    We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed.
    Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale.
    Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections)
    A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment.
    Thank you
    ALL MAJOR CREDIT CARDS & PayPal ACCEPTED
    Sell Smarter with
    Kyozou
    .
    Inventory and Ecommerce Management